9-5
MAINTENANCE DURING STORAGE
Once a month, recharge the battery.
The standard charging rate is 0.7A ×
5 to 10 hours.
PROCEDURE FOR RETURNING TO
SERVICE
Clean the entire vehicle.
Drain all the engine oil. Fill the
engine with fresh oil as outlined in
this manual.
Remove the spark plug. Turn the
engine a few times by pulling the
recoil starter. Reinstall the spark
plug.
Reinstall the battery.
NOTE: Be sure to connect the posi-
tive terminal first, then connect the
negative terminal.
Make sure that the vehicle is prop-
erly lubricated.
Perform the INSPECTION
BEFORE RIDING as listed in this
manual.
Start the vehicle as outlined in this
manual.