W3.260419
We reserve the right to alter specifications. 15www.swegon.com
NOTE! The function is only visible if the sensor has been
detected. The function is enabled automatically when
the sensor is detected.
Auto humidity control
Mode
Boost limit
Full boost limit
Sauna function
30 % + RH
Sauna boost 5 %
5 % + RH
RH now 30 %
The value “RH now”, the current moisture level, is
shown on the settings menu.
The ventilation starts to be boosted variably when the
extract air’s humidity has risen as much as the Boost
limit value. The Full boost limit value is used to set at
which humidity value in the extract air that full boost is
reached. Boost increases when the value decreases.
If you put automatic Sauna limit into service, the ven-
tilation is boosted with the set value during the sauna.
This function prevents any disruptive variations in the
fan speeds while the sauna is working.
3.3.8 Automatic air quality control
The function is available only on models equipped with
automatic air quality. Automatic air quality boosts the
ventilation variably according to the indoor air quality.
This function should always be set in conjunction with
commissioning.
The function can be activated and set from the Settings/
Smart Functions/Auto air quality control menu. NOTE!
The function is only visible if the sensor has been
detected.
Auto Air Quality control
Mode
Boost limit
Full boost limit 1400 ppm
800 ppm
AQ now 620 ppm
In use
Filter time 2 min
The settings menu shows the value “AQ now” the
current air quality level. The function is set by specifying
the boost limits where you want the ventilation boost
to start and the value at which you want the ventilation
unit to reach maximum boost. Appropriate values can
be established based on the “AQ now” value shown in
the menu.
If it seems that the ventilation system reacts too quickly
to changes in the air quality level, you can increase the
filtering time.
Important
Smart measurements: CO
2
, RH and VOC.
The absolute values in the measurement
result affect how well the control works.
!
!
3.3.9 Temperature boost
Temperature boost is available if an air heater has been
installed in the system, which is available as an acces-
sory, and if you have set room air as the control method
on the “Heating/cooling” method. The function boosts
the air flow so that the required room temperature is
reached.
The function can be activated and set from the Settings/
Smart Functions/Heating boost menu. The function can
be boosted by increasing the boost value.
Temperature boost
Mode
Cooling Gain
Use in away mode
5 %
Heating gain 5 %
In use

Table of Contents

Other manuals for Swegon CASA W3 Smart

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Swegon CASA W3 Smart and is the answer not in the manual?

Swegon CASA W3 Smart Specifications

General IconGeneral
BrandSwegon
ModelCASA W3 Smart
CategoryFan
LanguageEnglish

Related product manuals