8. Commissioning form
Function Factory setting Setting value
Fan speeds
Away, supply air fan 40 %
Away, extract air fan 40 %
Home, supply air fan 50 %
Home, extract air fan 50 %
Boost, supply air fan 65 %
Boost, extract air fan 65 %
Travelling, supply air fan 40 %
Maximum automatic boost, supply air fan 65 %
Smart settings
A
+
, Home limit 900 ppm
A
+
, Away limit 600 ppm
Cooker hood function, compensation (home) 20 %
Cooker hood function, compensation (boost change) 0 %
Cooker hood function, boost of cooker hood 0 %
Fahood function, operation of roof fan Not used
Central vacuum function, compensation 20 %
Air flows | NOTE! All the fan modes should be preset. Project planning values Setting value
Supply air, total l/s m
3
/h l/s m
3
/h
Away
Home
Boost
Extract air, total l/s m
3
/h l/s m
3
/h
Away
Home
Boost
Ventilation unit data | Write down the data on the ventilation unit identification plate for reference when the
need arises to contact a service company.
Preset by: Date:
Important
The supply air flow must be 2–10 % lower than the extract air flow.
Remember to explain the use of the item of optional equipment and how to service it to the
user/caretaker!
!