9 sy.uk
Set Safety Temperature
The following command sets the Power Off, Warning, and Re-Power temperatures. There is also
a command to enable or disable this feature:
SET OMEGA SAFE-TEMP-ONOFF ON
Enable MFS31-H safety temperature handling
SET OMEGA SAFE-TEMP-ONOFF OFF
Disable MFS31-H safety temperature handling
GET OMEGA SAFE-TEMP-ONOFF
Get current OMEGA SAFE-TEMP-ONOFF state
SET OMEGA SAFE-TEMP-VALUE x y z
Set shut down temperature x
Set warning temperature y
Set re-power temperature z
Default: x=75, y=70, z=65 (℃)
x>y>z>55
GET OMEGA SAFE-TEMP-VALUE
Get the current OMEGA safety temperature values
Note:
MFT31-H is designed to power the remote transmitters (iPoC capable) using the provided
48V PSU. It can also power non iPoC transmitters by using appropriate 24V PSU.
The MFT31-H can not be powered by the remote transmitters.
RJ-45 Wiring
Both connectors must be wired identically.
HDBaseT signals will NOT pass through any Ethernet device. The HDBaseT ports on this device
must be connected directly to the HDBaseT port of the remote Transmitters.
Please do make sure that the Cat6 cable uses 4 pairs of 23AWG solid copper wires. Do not use
inferior copper clad cables as these exhibit much higher resistances.