6000-100Ch4.fm Rev. D TimeVault™ User’s Manual 4-57
Function Commands Chapter 4: Serial or Telnet I/O Functions
You can see from the sample list below that “enabled”, “good”, and “tracked” satellites are
“current”. That means that the unit does not use any satellite with questionable
communication to calculate time, even if that satellite is enabled, visible and being
tracked.
Sample entry: F60<Enter>
The response is a current list, an example of which is:
F60 prn 1 bad enabled sig level= +0.00
F60 prn 2 bad enabled sig level= +0.00
F60 prn 3 good enabled tracked current sig level=+13.64
F60 prn 4 bad enabled sig level= +0.00
F60 prn 5 bad enabled sig level= +0.00
F60 prn 6 good enabled sig level= +0.00
F60 prn 7 bad enabled sig level= +0.00
F60 prn 8 bad enabled sig level= +0.00
F60 prn 9 bad enabled sig level= +0.00
F60 prn 10 bad enabled sig level= +0.00
F60 prn 11 bad enabled tracked sig level= +3.00
F60 prn 12 bad enabled sig level= +0.00
F60 prn 13 bad enabled sig level= +0.00
F60 prn 14 bad enabled sig level= +0.00
F60 prn 15 good enabled tracked current sig level=+22.77
F60 prn 16 bad enabled sig level= +0.00
F60 prn 17 good enabled sig level= +0.00
F60 prn 18 bad enabled sig level= +0.00
F60 prn 19 bad enabled sig level= +0.00
F60 prn 20 bad enabled tracked sig level= +3.00
F60 prn 21 good enabled tracked current sig level=+20.15
F60 prn 22 good enabled sig level= +0.00
F60 prn 23 good enabled tracked current sig level=+15.27
F60 prn 24 bad enabled sig level= +0.00
F60 prn 25 bad enabled tracked sig level= +3.47
F60 prn 26 good enabled sig level= +0.00
F60 prn 27 bad enabled sig level= +0.00
F60 prn 28 bad enabled sig level= +0.00
F60 prn 29 good enabled tracked current sig level=+21.46
F60 prn 30 bad enabled sig level= +0.00
F60 prn 31 good enabled tracked current sig level=+18.10
F60 prn 32 bad enabled sig level= +0.00