4-78 TimeVault™ User’s Manual 6000-100Ch4.fm Rev. D
Chapter 4: Serial or Telnet I/O Functions Extended Function Commands
To write the file to the flash, send the F100 BH command with the FTP host, file
path and name, and then send the following command:
F100 BU<Enter>
The unit responds:
Are you sure? (y/N)
If you answer “y” and press Enter, the unit executes the command.
As a safety feature, after sending this command, you have 10 seconds to respond
affirmatively (enter the letter “y”) to the confirmation prompt, after which the unit
executes the command and resets. Within that 10 second time period, any other response,
including no response, results in the unit canceling the command.
Unit example execution:
Burning Prog1
Burning file 182-9004v001.bin with size 688052 to
partition 1: sector :6
Sec: 6 re: 0
Sec: 7 re: 0
Sec: 8 re: 0
Sec: 9 re: 0
Sec: 10 re: 0
Sec: 11 re: 0
Sec: 12 re: 0
Sec: 13 re: 0
Sec: 14 re: 0
Sec: 15 re: 0
Sec: 16 re: 0
Flash successfully programmed CRC32 = 0x88841B88