EasyManua.ls Logo

Symmons Temptrol II - User Manual

Symmons Temptrol II
6 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Single Handle Pressure-Balancing Mixing Valve for Shower or Tub/Shower Application
INSTALLATION, OPERATION & SERVICE INSTRUCTIONS
Symmons valves and shower heads comply to all known standards, codes and specica-
tions: CSA B-125, ANSI A112.18.1M, ASSE 1016, EPA ‘92 etc.
Symmons shower heads are equipped with a 2.5 GPM (9.5 L/min) water and energy
saving ow restrictor.
LIMITED LIFETIME GUARANTEE
Symmons warrants to the original consumer purchaser that any TEMPTROL
®
Series, Allura™, or SYMMETRIX
®
product will be free of defects in material and workmanship during normal domestic use for the life of your
home. All other purchasers including industrial, commercial or business use are warranted for a period of
5 years from the date of purchase.
At our option, we will either have you send the defective part or product prepaid to us for inspection, or
we may elect to send you the replacement part or product without investigation. A replacement for any
defective part will be supplied FREE OF CHARGE for installation by the purchaser. Defect or damage caused
by the use of replacement parts other than Symmons Genuine Replacement Parts will void this warranty.
Symmons further warrants that any TEMPTROL Series, Allura, or SYMMETRIX product will be leak free and
drip free during normal domestic use for the life of your home. If the product should develop a leak or drip,
Symmons will provide FREE OF CHARGE the parts necessary to return it to good working condition.
Proof of purchase (original sales receipt) and a copy of the warranty registration card from the original
consumer purchaser must accompany all warranty claims. This warranty is applicable only to Symmons
TEMPTROL Series, Allura, or SYMMETRIX products purchased after July 1, 1998 and shall be effective from
the date of purchase as shown on the purchaser’s receipt.
Damage to the chrome and/or other decorative nishes on Symmons products may be a result of improper
handling or abusive treatment. Finishes should only be cleaned with a soft, damp cloth or sponge. Use of
polish, abrasive cleaners, solvents, or acid cleaners will damage the nish and void this warranty.
This warranty excludes product damage due to installation error, product abuse, or product misuse
whether performed by a contractor, service company or yourself. There are no other express warranties on
this product and ALL WARRANTIES OF MERCHANTABILITY AND OTHER IMPLIED WARRANTIES ARE LIMITED
IN ACCORDANCE WITH APPLICABLE LAW. SYMMONS INDUSTRIES, INC., EXPRESSLY DISCLAIMS CONTIN-
GENT LIABILITY AND CONSEQUENTIAL DAMAGE OF EVERY KIND. Since some states do not allow limita-
tions on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential
damages, the above limitation or exclusion may not be applicable. This warranty gives specic legal rights.
Other rights may vary from state to state.
To obtain warranty service, write to Symmons Industries, Inc., 31 Brooks Drive, Braintree, MA 02184-3804,
call our Customer Service Department at 1-800-SYMMONS, or visit www.symmons.com. If writing to us,
please include proof of purchase, the model number of the product with a brief description of the problem,
your name, address and phone number.
IMPORTANT: After completion of installation step 4, follow these instructions to set
the Temptrol II Limit Stop Screw. This valve is equipped with a limit stop screw to be
used to limit valve handle from being turned to excessively hot water discharge tem-
peratures. To adjust, remove dome cover, open valve to maximum desired tempera-
ture and turn in limit stop screw until it seats.
WARNING: FAILURE TO ADJUST THE LIMIT STOP SCREW PROPERLY MAY
RESULT IN SERIOUS SCALDING.
WARNING: THIS SHOWER SYSTEM MAY NOT PROTECT THE USER FROM SCALD-
ING WHEN THERE IS A FAILURE OF OTHER TEMPERATURE CONTROLLING
DEVICES ELSEWHERE IN THE PLUMBING SYSTEM.
For ADA compliance (Americans with Disabilities Act) consult ADAAG or your state
regulations for proper product choice and mounting locations.
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING
INSTALLATION. SAVE THIS MANUAL FOR FUTURE REFERENCE.

Questions and Answers

  • T
    Theresa WarnerAug 17, 2025
    How to fix a Symmons Temptrol II valve that leaks when shut off?
    • C
      Chelsea MayAug 17, 2025
      If your Symmons Plumbing Product valve leaks when shut off, the hot and cold washers are likely worn, or there's foreign matter (like solder or chips) between the washers and seat surfaces. Replace the hot and cold washers, and inspect the top surface on the hot and cold seats, replacing them if necessary.
  • S
    Stephen BaileyAug 20, 2025
    Why does my Symmons Temptrol II valve deliver hot water initially and then turn cold?
    • S
      Sharon WadeAug 20, 2025
      If your Symmons Plumbing Product valve delivers hot water when initially opened, and the water turns colder when rotating the handle counter-clockwise, it might be due to incorrect piping. The hot supply may be connected to the cold inlet, and vice versa. If you can access the piping, correct the connections. If not, contact the factory to order a reverse seat and tool (T-108 Kit). Older installations might also need a hot seat replacement (T-1).
  • J
    Joshua MccormickAug 23, 2025
    What to do if temperature varies without moving handle on Symmons Temptrol II Plumbing Product?
    • M
      Michael FischerAug 23, 2025
      If the temperature from your Symmons Plumbing Product varies without you moving the handle, it's likely that the pressure balancing piston inside the spindle assembly is blocked by foreign matter. Follow these steps: With the valve open halfway, remove the handle and gently tap the spindle using a plastic hammer. If the issue persists, completely remove the spindle assembly and tap the handle end against a solid object to dislodge the piston. Soaking the assembly in household vinegar can also help dissolve any foreign matter.
  • M
    Michele OsborneAug 25, 2025
    Why is the water volume inconsistent when adjusting the temperature on my Symmons Temptrol II Plumbing Product?
    • S
      Steven FisherAug 26, 2025
      If the temperature control handle of your Symmons Plumbing Product is turned from cold to hot (or hot back to cold) and the water volume from the spout or head isn't consistent, it's probably because the pressure balancing piston in the spindle assembly is blocked by foreign matter. With the valve open halfway, take off the handle and tap the spindle with a plastic hammer. If that doesn't work, fully remove the spindle assembly and tap the handle end against something solid to free the piston. You can also try soaking it in household vinegar to dissolve any debris.
  • J
    Jennifer OdonnellAug 27, 2025
    Why does my Symmons Temptrol II have low hot water pressure?
    • D
      david81Aug 27, 2025
      If your Symmons Plumbing Product valve delivers sufficient cold water but little hot water (or the reverse), the pressure balancing piston housed in the spindle assembly may be blocked by foreign matter. With the valve open halfway, remove the handle and tap the spindle with a plastic hammer. If the problem is not resolved, remove the spindle assembly completely and tap the handle end against a solid object to free the piston. Soaking it in household vinegar can also help remove any foreign matter.
  • V
    Virginia BrownAug 30, 2025
    What to do if Symmons Temptrol II Plumbing Product temperature reduces gradually during use?
    • A
      Amber DoyleAug 30, 2025
      If the delivery temperature of your Symmons Plumbing Product valve gradually decreases during use, requiring you to turn the handle to hotter positions to maintain a constant temperature, you may be experiencing an overdraw on the hot water supply, meaning you are running out of hot water. To fix this, reduce the maximum flow by adjusting the volume control on the valve or showerhead. This will allow for a longer period of use before the hot water supply is depleted.
  • B
    Brittany NealSep 1, 2025
    Why won't my Symmons Temptrol II valve pass water?
    • K
      kerri11Sep 2, 2025
      If your Symmons Plumbing Product valve will not pass water, ensure that both the hot and cold water supplies are turned on. The valve will not operate unless both hot and cold water pressure are active.
  • J
    Jacob MccoySep 4, 2025
    What to do if the Symmons Control Unit temperature handle affects water volume?
    • C
      Cindy RodriguezSep 4, 2025
      If the temperature control handle is turned from cold to hot (or vice versa) and the water volume from the spout or head isn't constant, the pressure balancing piston in the spindle assembly may be blocked by foreign matter. With the valve open halfway, remove the handle and tap the spindle with a plastic hammer. If that doesn't work, remove the spindle assembly completely and tap the handle against a solid object to free the piston. Soaking it in household vinegar can also help dissolve any foreign matter.
  • K
    Kerry RuizSep 6, 2025
    Why does the Symmons Control Unit temperature gradually reduce during use?
    • J
      James WatkinsSep 7, 2025
      If the valve delivery temperature reduces gradually during use, requiring you to turn it to hotter positions to maintain a constant temperature, it's likely due to an overdraw on the hot water supply. To resolve this, reduce the maximum flow by using the volume control adjustment on the valve or shower head. This will allow for a longer period of use before overdrawing the hot water supply.
  • G
    George PriceSep 9, 2025
    What to do if Symmons Control Unit valve leaks when shut off?
    • M
      Mr. Jerome TorresSep 9, 2025
      If the Symmons Control Unit valve leaks when shut off, the hot and cold washers may be worn, or foreign matter (like solder chips) may be trapped between the washers and seat surfaces. You should replace the hot and cold washers and inspect the top surface on hot and cold seats, replacing them if necessary.

Summary

Product Overview and Guarantee

Installation, Operation, and Service Overview

General guide to the valve's functionality and maintenance procedures.

Limited Lifetime Guarantee

Explains the warranty terms and conditions for the product.

Critical Safety Adjustments

Instructions for setting the limit stop screw and important safety warnings.

Installation Guide

Tools and Rough-in Requirements

Lists necessary tools and specifies rough-in dimensions for wall installation.

Tub;Shower System Piping

Details how to connect piping for shower heads and tub spouts.

Wall Preparation and Valve Mounting

Steps for preparing the wall and securing the valve body.

Final Installation Steps

Includes limit stop screw setting and system flushing.

Advanced Installation and Operation

Back-to-Back Installation Methods

Guidance for installing valves on opposite sides of a wall.

Valve Operation Principles

How to control temperature and water flow with the handle.

Care and Cleaning Instructions

Proper methods for cleaning and maintaining the valve's finish.

Fiberglass Wall Installation

Specific procedures for mounting the valve in non-traditional wall materials.

Service and Troubleshooting

Seat Removal Tools and Procedure

Details tools and steps for replacing hot and cold valve seats.

Troubleshooting Common Issues

Addresses problems like no water flow or leaks with solutions.

Parts Breakdown

Individual Parts List

Enumerates individual components and their part numbers.

Composite Parts List

Lists pre-assembled part kits and their associated components.

Symmons Temptrol II Specifications

General IconGeneral
ModelTemptrol II
MaterialBrass
Maximum Pressure125 psi
WarrantyLimited Lifetime
Inlet Connection Size1/2 inch
Outlet Connection Size1/2 inch
Temperature ControlPressure Balancing
Maximum Temperature180°F
ADA CompliantYes
FinishChrome

Related product manuals