Place the DC power
sense cables here if using
your own power source.
Place the DC sense
cables here if using.
Important
Note:
Only M10 (brass) fas-
teners provided should
be used on all DC-con-
nections on the laser.
Electrical Connections (Continued):
Warning!
Serious
personal
injury
The Quick Start Plug bypasses the laser’s safety interlock function poten-
tially exposing personnel to hazardous invisible infrared laser radiation.
Remove DC power before installing or removing the Quick Start Plug. Please
refer to the (Connecng-laser connecons & the following Quick Start Plug) sec-
ons in the p250 Operator’s Manual.
Control Connections:
21. Connect the Ethernet & BNC (Laser Control) cabling per the SYNRAD marking head QSG. If using the
QSP, see your Laser’s Operators Manual. If you aren’t using a SYNRAD marking head, go to the next
section.