PAGE 18
Anleitung EAG80_26_00_2017_03_28_GB
Version 28.04.2017
4.3 Menu filter settings (fILte)
FILte
Filter selection
Filter speed
Filter number of values
Weight difference
4.3.1 Filter selection
FIL
Here the weight slowdown can be activated
AuS Slowdown of scales deactivated (SF, FIL A and SPrun will be ignored)
EIn Slowdown of scales activated (Setting via SF, FIL A and SPrun)
4.3.2 Filter speed
SF
Here you determine the speed of the weight measuring.
Values from 1 – 255 can be entered.
Value 1= quick measurement
Value 255 = slow measurement
4.3.3 FIL A
FIL A
Number of mean values
4.3.4 Weight difference
SPRuN
Weight difference from which the scales quickly update the weight (without mean value/filter)