Version 28.04.2017
4.4 WAAGE Waage
Waage
Display steps
Weighing elements basic settings
Set scales to zero
Weight factor
Zero point adjustment
Scales adjustment with weights
4.4.1 AuFLo
Auflo
Selection of display steps 0,01; 0,02; 0,05; 0,1; 0,2; 0,5; 1; 2; 5; 10; 20; 50
4.4.2 StAbE
Stabe
Basic settings of weighing elements , adjustment via key data (quantity / max load / mV/V)
StAbA quantity of connected weighing elements
LASt maximum load of connected weighing elements (see type plate of weighing element)
StAbS mV/V value of connected weighing element (see type plate of weighing element)
4.4.3 nuLLP
NULLP
Set scales to 0 when zero button is activated
4.4.4 Facto
FaCTO
Input of weight factor
4.4.5 0-JUS
0-jUs
0-point adjustment for better readjustment with high dead load
4.4.6 JUSt
JUST
Scales adjustment with weights
0-JuS 0-point adjustment
G-JuS Weight entry for adjustment