29
Function F_
Function Description
Unit Range
Factory
setting
Page Note
Reverse Lock-Out 22
0: REV run
1: REV run Lock-Out
1 0 ~ 1 0 32
Momentary power
loss
23
0: enabled
1: disabled
1 0 ~ 1 0 33
Auto restart 24 Number of Auto-restart times 1 0 ~ 5 0 33
Factory setting 25
010: Constants initialization to 50Hz system
020: Constants initialization to 60Hz system
34 *2
SP2 frequency 26 SP2 frequency 0.1Hz 1.0~200Hz 20 34 *4
SP3 frequency 27 SP3 frequency 0.1Hz 1.0~200Hz 30 34 *4
Direct start 28
0:enable
1:disable
1 0 ~ 1 1 34 *5
Software version 29 CPU program version 35
Fault Log 30 Fault log for three faults. 35
NOTE:
*1: Indicate this parameter can be adjusted during running mode.
*2: Please refer to F_25.
*3: If the setting range is above 100, the setting unit becomes 1.
*4: New function for CPU version V1.9 and above.
*5: New function for CPU version V2.1 and above
Parameter function description
F_00 Factory adjustment parameter. Do not change.
F_01 : Acceleration time = 0.1 ~ 999 sec
F_02 : Deceleration time = 0.1 ~ 999 sec
1. Acceleration / Deceleration time calculation formula:
Setting Frequency Accelerate time = F_01 x
60 Hz
Setting Frequency Decelerate time = F_02 x
60Hz
F_01 F_02
Hz
Time

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the T-Verter E2-201-*1 Series and is the answer not in the manual?

T-Verter E2-201-*1 Series Specifications

General IconGeneral
BrandT-Verter
ModelE2-201-*1 Series
CategoryController
LanguageEnglish

Related product manuals