EasyManua.ls Logo

Tait TB9300 - Page 34

Tait TB9300
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34 Description TB9300 Installation and Operation Manual
© Tait International Limited April 2024
Table 1.1 PMU DC voltage limits
a
Parameter
Voltage Range
12V PMU 24V PMU 48V PMU
User-programmable Alarms
b
Low Battery Voltage
High Battery Voltage
10V to 14V
14V to 17.5V
20V to 28V
28V to 35V
40V to 56V
56V to 70V
User-programmable Limits
b
Startup Voltage (after shutdown)
Shutdown Voltage
10.9V to 15V ±0.3V
10V to 13.5V ±0.3V
21.8V to 30V ±0.5V
20V to 27V ±0.5V
43.6V to 60V ±1V
40V to 54V ±1V
Battery Protection (Fail-safe) Limits
Startup Voltage
Undervoltage Shutdown
Overvoltage Shutdown
Overvoltage Shutdown Reset
10.8V +0.2V
9.5V +0.3V
18.1V +
0.3V
17.1V +0.3V
21.6V +
0.5V
19V +0.5V
36.2V +
0.5V
34.2V +0.5V
43.2V +
1V
38V +1V
72.4V +
1V
68.4V +1V
a. The information in this table is extracted from the Specifications Manual. Refer to the latest issue of this manual
for the most up-to-date and complete PMU specifications.
b. Using the base station’s WebUI.

Table of Contents

Other manuals for Tait TB9300