EasyManua.ls Logo

Takagi GS-2000W-AU - MAINTENANCE AND SERVICE; UNIT DRAINING and FILTER CLEANING

Takagi GS-2000W-AU
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
MAINTENANCE AND SERVICE
The water heater should be checked at least once a year or as necessary by a licensed technician.
If repairs are needed, any repairs should be done by a licensed technician.
The water heaters lifeme may be extended by frequent maintenance.
WARNING
Turn o the electrical power supply and close the manual gas control valve and the manual
water control valve before servicing.
Clean the cold-water inlet lter. (Refer to diagram below.)
Be sure that all openings for combuson air are not blocked. If blocked, remove any obstrucon.
Check that the opening for exhaust is not blocked. If blocked, shut o the water heaters combuson.
Aer a while, remove any obstrucon. DO NOT touch while burning because you might get burnt due
to high temperature.
Check the gas pressure.
Keep the area around the water heater clear. Remove any combusble materials, gasoline or any
ammable vapors and liquids.
UNIT DRAINING and FILTER CLEANING
1. Close the manual gas shut o valve.
2. Turn o the power supply to the water heater.
3. Close the manual water shut o valve.
4. Open all hot water taps in the house (Bathroom, kitchen, laundry room, etc.). When the residual water
ow has ceased, close all hot water taps.
5. Have a bucket or pan to catch the water from the units drain plugs. Unscrew the drain plugs to drain
all the water out of the unit.
6. Wait a few minutes to ensure all water has completely drained from unit.
7. Clean the lter: Check the water lter located within the cold inlet. With a ny brush, clean the water
lter of any debris which may have accumulated and reinsert the lter back into the cold water inlet.
8. Securely screw the drain plugs back into place. Hand-ghtenonly.
3. REMOVE BY TURNING
COUNTERCLOCKWISE AND
THEN CLEAN AND REPLACE
1. TURN OFF THE WATER
INLET SUPPLY VALVE.
2. OPEN A HOT WATER
TAP TO RELEASE THE
LINE PRESSURE.
lter

Related product manuals