23
WATER HEATER
PROBLEM POSSIBLE SOLUTIONS
Unit does not ignite when water
goes through the unit.
Is the ow rate over 3.0 l/min? (p. 18)
Check for the lter on cold water inlet. (p. 21)
Check for reverse connecon and cross connecon.
If you use the remote controller, is the power buon turned on?
(p. 18,19)
The fan motor is sll spinning aer
operaon has stopped.
This is normal. Aer operaon has stopped, the fan motor keeps
running for 15 to 75 seconds in order to re-ignite quickly, as well as
push all exhaust gas out of the ue.
REMOTE CONTROLLER (OPTIONAL)
PROBLEM POSSIBLE SOLUTIONS
Remote controller does not display
anything when the power buon is
turned on.
Press the ON/OFF buon.
If the lamp does not light:
Make sure the unit has power supply.
Make sure the connecon to the unit is correct.(p. 16)
An ERROR code is displayed. Please see the p.24
Remote controller can not change
the set temperature.
Is priority lamp lit?
If it is not, press the priority buon aer closing all hot water taps.