Installaon
Installaon Manual
-DIPswitch settings for Vent length-
Ventlength Two-pipeandSinglepipe
5to50ft.
(DEFAULT)
No. 6 : ON
No. 7 : OFF
51to100ft.
No. 6 : OFF
No. 7 : OFF
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6 7 8 9 10
Ventlength Two-pipe
5to20ft.
(DEFAULT)
No. 6 : ON
No. 7 : OFF
21to40ft.
No. 6 : OFF
No. 7 : OFF
41to70ft.
No. 6 : ON
No. 7 : ON
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6 7 8 9 10
Set DIPswitches shown in the tables below depending on the vent length. Only adjust switches with a black
square. Black squares indicate the position of the switch.
Ventlength Singlepipe
5to45ft.
(DEFAULT)
No. 6 : ON
No. 7 : OFF
46to70ft.
No. 6 : OFF
No. 7 : OFF
OFF
ON
1 2 3 4 5 6 7 8 9 10
OFF
ON
1 2 3 4 5 6 7 8 9 10
Ventlength Singlepipe
5to6.5ft.
No. 6 : ON
No. 7 : ON
OFF
ON
1 2 3 4 5 6 7 8 9 10
2 inch venting
3 inch venting
4 inch venting