EasyManuals Logo
Home>Takagi>Water Heater>T-K1S

Takagi T-K1S User Manual

Takagi T-K1S
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
- 12 -
To re-start your heater, follow these steps:
1. Make sure all hot water taps are closed
and the drain plugs are securely attached.
2. Purge the water line of debris.
3. Open the manual water shut-off valve
located on the water supply line.
4. Open all the hot water taps to verify water
flows to the taps. Then close the hot water
taps.
5. Open the manual gas shut-off valve located
on the gas supply line.
6. Turn on the power supply to the T-K2
Water Heater.
Note: Do not reverse the hot outlet and cold
inlet connections to the T-K2 Water Heater.
This will not activate the water heater.
Pressure Relief Valve
The FLASH T-K2 has a high-temperature shut
off switch built in as a standard safety feature
(called a Hi-Limit switch) therefore a “pressure
only” relief valve is required.
This unit does not come with an approved
pressure relief valve. An approved pressure
relief valve must be installed on the hot water
outlet. The pressure relief valve must conform
to ANSI Z21.22 or CAN 1-4.4 and installation
must follow local code.
The discharge capacity must be at least
185,000 BTU/hr. The discharge piping for the
pressure relief valve must be directed so that
the hot water cannot splash on anyone or on
nearby equipment. Attach the discharge tube
to the pressure relief valve and run the end of
the tube to within 6" from the floor. This
discharge tube must allow free and complete
drainage without any restrictions.
If the pressure relief valve installed on the T-K2
discharges periodically, this may be due to a
defective thermal expansion tank or defective
pressure relief valve.
The pressure relief valve must be manually
operated periodically to check for correct
operation.
ELECTRICAL CONNECTIONS
WARNING: Follow the electrical code
requirements of the local authority having
jurisdiction. In the absence of such
requirements, follow the latest edition of the
National Electrical Code ANSI/NFPA 70 in the
U.S. or the latest edition of CSA C22.1
Canadian Electrical Code, Part 1, in Canada.
The heater must be electrically grounded. Do
not attach the ground wire to either the gas or
the water piping. Plastic pipe or dielectric
unions may isolate the water heater
electrically.
CAUTION: When servicing or replacing parts
within the T-K2, label all wires prior to
disconnection to facilitate an easy and error
free reconnection. Wiring errors can cause
improper and dangerous operation. Verify
proper operation after servicing.
The FLASH T-K2 water heater requires AC
120V 60 Hz electrical power supply that is
properly grounded.
An on/off switch controlling the main power
to the T-K2 must be provided for service
reasons;
Connect the power supply to the T-K2
exactly as shown in the wiring diagram;
A green screw is provided in the junction box
to ground the connection.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Takagi T-K1S and is the answer not in the manual?

Takagi T-K1S Specifications

General IconGeneral
BrandTakagi
ModelT-K1S
CategoryWater Heater
LanguageEnglish

Related product manuals