- 25 -
For TM-RE10 Port.
Use 18 Gage Wire.
No Polarity
It has four Ports. Each port can
connect up to five T-M1. No Polarity.
This connects “201” connecter
in the first T-M1
LP or Natural Gas, Please don’t
change these switch, Factory already
set it correctly.
When unit is firing, this RED LED will
be ON
For Single or Multi mode JUMP cable.
For Multi mode, permanently pull out.
To switch to Multi mode, this jump cable has
to be removed from the T-M1 computer
board permanently, but please keep this
jump connector safety stored for future
maintenance (this jumper is located behind
the “do not remove” label.
Error signal LED, this LED shows for unit error,
also it will show on RE-10 and RE20. Error codes
are “Error Code’ section in this Installation Manual.
Standby Light with Green LED, ON light mean Unit
is ready to fire.
When Unit is ON, upper RED LED will be ON also.