16
English
TROUBLESHOOTING
Use the inspections in the table below if the tool
does not operate normally. If this does not remedy
the problem, consult your dealer or the Tanaka
dealer.
Condition Cause Remedy
Engine does not
start
Fuel
system
Fuel tank is empty or fuel level is
low
Fill the fuel tank with the correct fuel
mix (25:1-50:1)
Fuel tank contains old fuel
(offensive odor)
Replace with new fuel
Too much fuel is absorbed and
spark plug is wet
1. Disconnect the spark plug and allow
to dry
2. Pull the starter handle 5 or 6 times
to remove the surplus fuel
3. Attach the spark plug
4. Set the choke lever to RUN position
and pull the starter handle
Fuel fi lter is clogged with dirt Clean the fuel fi lter
Fuel pipe is bent or disconnected Ensure that the fuel fl ows smoothly
Carburetor malfunction Contact Tanaka dealer
Electrical
system
Stop switch lead has short-circuited Contact Tanaka dealer
Spark plug is dirty Replace or clean the spark plug
Electrode gap is too big Adjust the gap to 0.6mm
Poor connection between high
tension cable and spark plug
Reconnect
Electrical system malfunction Contact Tanaka dealer
Other
Muffl er exhaust port is clogged with
carbon
Contact Tanaka dealer for repair
000BookTCG24EBSPUS.indb16000BookTCG24EBSPUS.indb16 2014/03/2615:11:372014/03/2615:11:37