EasyManua.ls Logo

TanGO TX1 - Page 13

Default Icon
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
Table 1.5 Sensor specifications
Gas type (abbreviation)
Part Number
Carbon Monoxide with low Hydrogen cross-sensitivity
(CO/H
2
Low)
17155823
Properties
Category
Toxic
Technology
Electrochemical
DualSense
®
capable
Yes
Operating conditions
Temperature range
a
-20 to +50 °C
(-4 to +122 °F)
RH range
a
15-95%
Performance
Sensitivity
Measurement range
0−1000 ppm
Measurement resolution
1 ppm
Calibration
Calibration gas and concentration/balance gas
e
100 ppm CO/Air
Calibration gas flow rate 0.5 L/m ± 10%
Accuracy
b
Accuracy at time and temperature of calibration ± 5% (0300 ppm)
± 15% (3011000 ppm)
Accuracy over sensor’s full temperature range
± 15%
Response Time
d
T50 9 s
T90 18 s
Recovery Time
d
T50 9 s
T10 18 s