2. OPERATION
2.4.1.1. Drainage of the pump (T80 T825)
After the CIP procedure, the pump usually has to be
drained from the CIP fluid. The Tapflo sanitary series is
supplied with a hygienic stand, enabling 360° rotation of
the pump unit.
1) Disconnect the pump from the piping.
2) Simply loosen the two socket head cap screws (pos. 174
see chapter 5. SPARE PARTS), rotate the pump 180°
and let the remaining fluid drain off. The airline may be
left connected during this operation.
3) Rotate back to normal position, connect the pump with
the piping and fix the socket head cap screws (pos. 174).