95
Malfunctions
Malfunction Possible causes Troubleshooting Page
Machine without function
No power supply
Insert the plug into the mains sock-
et.
Machine is switched off Switch on the main switch 88
Power supply cord defect Contact your service partner
Brush unit or suction unit cannot be
turned off
Error in the electronic system or in
the control panel
Switch off the machine (main
switch) and remove the plug from
the mains socket.
Contact your service partner
88
Brush does not rotate
Machine overload, overload switch
Release the switch drive and press
again
88
Motor rotates, brush does not
Drive belt broken
Contact your service partner
Poor suction performance Floor re-
mains wet Soiled water is not vacu-
umed up
Suction not switched on Press suction unit button 88
Float closes the inlet opening on the
suction unit (overfill protection recov-
ery tank)
Recovery tank full, check
Check float for functionality
88
Suction hose not connected Connect suction hose 89
Squeegee not on the floor
Check squeegee suspension for
functionality
89
Blades worn out
Replace blades
94
Hose or squeegee clogged (e.g.
pieces of wood, remnants)
Remove any foreign matter
Suction filter clogged Remove any foreign matter 88
Check the tank cover's gasket for
cracks/dirt
Clean the gasket and replace if de-
fective
Dirt sieve full
Remove the dirt sieve.
Empty the dirt sieve by tapping it
and rinse it under running water
Insufficient cleaning solvent supply
Cleaning solution tank (fresh water
tank) empty
Check cleaning solution tank
(fresh water tank) and fill with wa-
ter
91
Fresh water tank filter blocked Cleaning the fresh water tank filter 92
Cleaning solvent button switched off Press cleaning solvent button 88
Foam or liquid leaking from the ma-
chine
Float malfunction
Switch the suction unit off
Check the float to make sure it is
fully functional and repair any fault