Troubleshooting
Troubleshooting
No product being dispensed (draw valve
open and machine in “AUTO” mode).
Cause: Inadequate mix in the mix hopper.
Remedy: Fill mix hopper with mix.
Cause: Beater motor out on reset.
Remedy: Allow the motor to cool and then press
the reset button.
Cause: Circuit breaker off or blown fuse.
Remedy: Turn breaker on or replace fuse.
Cause: Freeze-up in the mix inlet hole.
Remedy: Call service technician to adjust mix hopper
temperature.
Cause: Beater rotating counter-clockwise from
operator end.
Remedy: Contact service technician to correct
rotation to clockwise from operator end.