USER INTERFACE
5-3
Model C302
User Interface
5
Table 5-1
The following are explanations of the possible faults and
the display screens. Lines 2 and 3 indicate the faults
found in freezing cylinders 1 and 2 respectively.
1. NO FAULT FOUND—No fault conditions are
apparent.
2. BEATER OVERLOADBeater motor is out on
overload. When this fault occurs, the affected side of
the machine automatically turns off. The fault clears
when the condition is corrected.
3. CHK REFRIG SYS PSICompressor is out on high
head pressure. When this fault occurs, the machine
automatically turns off. The fault clears when the
condition is corrected.
4. THERMISTOR SHORTOne or both of the barrel
(freezing cylinder) thermistor probes are faulty.
5. THERMISTOR OPENOne or both of the barrel
(freezing cylinder) thermistor probes are faulty.
6. SYRUP PRESS LOWWhen the syrup out indicator
displays a lack of syrup, the barrel will enter a Hold
mode. At this time, no refrigeration or product flow
from the flow control will be allowed. Only the beater
will operate. When the syrup is satisfied the barrel
will refill the product tank and then automatically
return to the Auto mode. The fault message and the
warning tone will clear. (See Syrup Out Indicator on
page 5-7.)
Fault Messages
Beater Overload Beater is out on overload.
Chk Refrig Sys Psi Out on compressor high
pressure cut-out.
Thermistor Short Shorted thermistor probe.
Thermistor Open Open thermistor probe.
H
2
O Pressure Low Water pressure is low.
CO
2
Pressure Low CO
2
pressure is low.
Syrup Pressure Low Syrup is no longer present.
BRL Temp 2 High Freezing cylinder temperature
is above 120°F (49°C).
BRL Not Cooling Freezing cylinder is not
cooling after 5 minutes.
No Fault Found No fault conditions are
apparent.
FAULT DESCRIPTION
L: NO FAULT FOUND
R: NO FAULT F OUND
CLR +++ SEL
FAULT DESCRIPTION
L: BEATER OVERLOAD
R: BEATER OVERLOAD
CLR +++ SEL
FAULT DESCRIPTION
L: CHK REFRIG SYS PSI
R: CHK REFRIG SYS PSI
CLR +++ SEL
FAULT DESCRIPTION
L: THERMISTOR SHORT
R: NO FAULT FOUND
CLR +++ SEL
FAULT DESCRIPTION
L: THERMISTOR OPEN
R: NO FAULT FOUND
CLR +++ SEL
FAULT DESCRIPTION
L: NO FAULT FOUND
R: SYRUP PRESS LOW
CLR +++ SEL