6-10
OPERATING PROCEDURES
Model C302
Operating Procedures
6
To disassemble the Model C302, the following items will
be needed:
• Two cleaning pails
• Necessary brushes (provided with freezer)
• Cleaner
• Single-service towels
Draining Product from the Freezing
Cylinders
1. Press the BEATER (- - -) key. This will allow the
beater to operate, and CO
2
pressure will be
maintained to push the product from the freezing
cylinder. Open the draw valve and drain the product
from the machine until the CO
2
begins to jet.
Figure 6-38
2. When all the product has been drained from the
freezing cylinder, close the draw valve and press the
OFF (<- -) key. Discard this product.
Figure 6-39
3. Repeat step 1 through step 2 for the other freezing
cylinders.
Rinsing
Note: The following instructions are for one pair of
freezing cylinders under an LCD.
1. To place the left cylinder in the Rinse mode, press
the MENU (SELECT) key. Move the cursor by
pressing the AUTO (- ->) key until the third line
indicates RINSE / SANITIZE.
2. Press the MENU (SELECT) key. Move the cursor
under RINSE by pressing the OFF (<- -) key twice.
3. Pressing the MENU (SELECT) key will give you the
option for rinsing the left freezing cylinder. Move the
cursor under the word YES. Pressing the MENU
(SELECT) key at this time will start the beater motor
and deliver water and CO
2
to the left cylinder.
4. Allow the rinse water to flow into the cylinder until it is
approximately two thirds full. With a pail under the
door spout, open the draw valve and drain the rinse
water. Repeat this procedure until the rinse water
being drawn is clear.
5. Repeat step 3 through step 4 for the right freezing
cylinder.
Note: There is a left and a right freezing cylinder for
each LCD.
6. When draining is complete, press the OFF (<- -) key.
OPERATOR MENU
ABCDEFGH
I
RINSE / SANITIZE
LES>----<
RINSE / SANITIZE
RINSE SANITIZE EXIT
----
LES>----<
RINSE
LEFT SIDE YES NO
---
LES>----<
RINSE
RIGHT SIDE YES NO
---
LES>----<