22
Systems, Controls and Operations
Model C602
MIX LEVEL AUDIBLE
The MIX LEVEL AUDIBLE option, when enabled,
will alert the operator with an audible tone when
there is mix low or mix out condition. The following
screen is displayed upon selecting this option. (See
Figure 41.)
MIX LEVEL AUDIBLE
ENABLED
> Enable
Disable
Figure 41
Disable the audible tone feature by selecting the
OPTIONAL FLAVOR symbol
to move the arrow
to DI SABLE. Select the CALIBRATION symbol
to save the new setting and return to the Menu. The
control panel icons for Mix Low and Mix Out will
illuminate as the mix level drops in the hopper but
the audible tone will be disabled.
FAULT DESCRIPTION
The FAULT DESCRIPTION display will indicate if
there is a fault with the freezer and the side of the
freezer where the fault occurred. When no faults are
detected the following screen will be displayed. (See
Figure 42.)
FAULT DESCRIPTION
L: NO FAULT FOUND
R: NO FAULT FOUND
Figure 42
Select the CALIBRATION symbol to display the
next fault found or return to the Menu if no other
faults exist. Selecting the CALIBRATION symbol
any time faults are displayed will clear the faults if
corrected, upon returning to the Menu screen.
Listed below are the variable messages which will
appear, along with an explanation for the corrective
action.
NO FAULT FOUND - There was no fault found in
the freezer. Nothing will appear on the screen after
this variable message appears.
BEATER OVERLOAD - Press the beater reset
button firmly for the side of the freezer with the fault.
HPCO COMPRESSOR - Place the power switch in
the OFF position. Wait 5 minutes for the machine to
cool. Place the power switch in the ON position and
restarteachsideinAUTO.
HOPPER THERMISTO R BAD - Place the power
switch in the OFF position. Replace the bad probe.
BARREL THERMISTOR BAD - Place the power
switch in the OFF position. Replace the bad probe.
GLYCOL THERMISTOR BAD - Place the power
switch in the OFF position. Replace the bad probe.
LOCKOUT HISTORY
The LOCKOUT HISTORY screen displays a history
of the last 40 soft locks, hard locks, brush clean
dates, or aborted heat cycles. Page numbers are
indicated in the upper right hand corner. Page 1
always contains the most recent failure. (See
Figure 43.)
LOCKOUT HISTORY 2
00/00/00 00:00
REASON
>Exit
Figure 43
The second line of the screen displays the date and
time a failure occurs. The third line indicates the
reason for a failure, or will indicate if a successful
brush cleaning has occurred. Some failures occur
with multiple reasons. When this occurs, a page will
be generated for each reason.
Select the AUTO symbol
or OPTIONAL FLAVOR
symbol
to advance forward or backward to view
each screen.