29
Model C602
Systems, Controls and Operations
BEATER OFF DELAY
The BEAT ER OFF DELAY allows the service
technician to set the time the beater motor continues
to run after the compressor has cycled off. The
range for the delay time is 0 seconds to 10 seconds
and is adjustable in one-second intervals. Use the
AUTO symbol
or t he OPTIONAL FLAVOR
symbol
to adjust the setting. The recommended
setting is 0 seconds for shake and soft serve
applications.
The Left Beater OFF Delay screen is displayed first
(See Figure 66.)
BEATER OFF DELAY
LEFT : 0 SECONDS
Figure 66
Advance to the next screen for the right side setting
or return to the service menu by selecting the
CALIBRATION symbol
. See Figure 67.)
BEATER OFF DELAY
RIGHT : 0 SECONDS
Figure 67
MIXPUMPOFFDELAY
The MIX PUMP OF F DELAY allows the service
technician to set the amount of time the mix pump
runs after the draw valve has closed (switch open).
This adjustment is for the soft serve mix pump only.
The range is for the Pump Off Delay is 0 – 30
seconds and is adjustable in 1- second intervals.
Use the AUTO symbol
or the OPTIONAL
FLAVOR symbol
to adjust the setting. The
recommended setting is 10 seconds. (See
Figure 68.)
MIXPUMPOFFDELAY
RIGHT : 10 SECONDS
Figure 68
Select the CALIBRATION symbol
to return to the
Service Menu.
WHITE SPOT ADJUST
This option allows the service technician to set the
White Spot Adjustment for each syrup flavor. (See
Figure 69.)
WHITESPOT ADJUST
TIME : 0.2 SEC
CHOCOLATE
Figure 69
Select the AUTO symbol
to increase the
whitespot setting or the OPTIONAL FLAVOR
symbol
to decrease the setting.
The recommended White Spot Setting for standard
shakes is 0.2 seconds. The recommended setting
for Triple Thick Shakes is 0.4 seconds.
Select the CALIBRATION symbol
to save the
setting and advance to the Whitespot Setting for the
next flavor.