47
Model C602
Systems, Controls and Operations
040608
4. During the program initialization, (Language,
System Data, Config Data, Lockout Data) the
RESET TO DEFAULTS message will display
on the screen. (See Figure 91.)
SERVICE REQUIRED
NVRAM FAULT
RESET TO DEFAULTS
> PRESS TO CLEAR
Figure 91
5. Clearing the Defaults message will initiate the
Safety Timeout screen. (See Figure 92.)
SAFETY TIMEOUT
ANY KEY ABORTS
Figure 92
6. After 60 seconds or selecting a key to abort the
Safety Timeout the POWER SWITCH OFF
message will appear on the screen. (See
Figure 93.)
Power Switch OFF
_______________
_______________
Unit Cleaned
Figure 93
7. Place the Power switch to ON, clear the two
information screens that appear, and the UNIT
CLEANED message will be displayed. (See
Figures 94, 95, and 96.)
Reset to Defaults
<-- Press to Clear
Figure 94
Lockout CRC Error
<-- Press to Clear
Figure 95
Unit Cleaned
Figure 96
8. Immediately access the Service Menu and
enter the proper program settings to complete
the chip installation.