55
Model C602
Systems, Controls and Operations
040608
Shake Dispensing Alignment Procedure
There are five areas that must be properly aligned in
the shake draw mechanism.
S Actuator Plate
S Spinner Motor Bracket
S Solenoid Valve
S Spinner Motor
S Spinner Coupling
All adjustments must be performed with the freezer
door assembled and installed, with the hand screws
secure. Tighten the hand screws in a criss- cross
pattern so the door is drawn up flush on the cylinder
face. (See Figure 97.)
Figure 97
ITEM DESCRIPTION
A ACTUATOR PLATE
B SPINNER MOTOR BRACKET
C SOLENOID VALVE
D SPINNER MOTOR
E SPINNER COUPLING
F BUMPER
Actuator Plate
The actuator plate (lifter) should be centered to fit in
the draw valve slot. (See Figure 98.)
Figure 98
To adjust the alignment, perform the following
steps:
Step 1
With the bumper access plate removed and the
bumper screw loose, align the actuator with the slot
inthedrawvalve(sidetosidealignment).
Step 2
Secure the bumper screw. Check to make sure the
bottom of the solenoid plunger is secured to the
actuator plate.
The actuator should slide easily into the draw valve
slot when the freezer door assembly is installed.
(See Figure 99.)
Figure 99