Step 7
Lower the solenoid until the top of the plunger
contacts the top surface (stopping point) inside the
coil body. (See Figure 102.) Make sure the solenoid
is aligned vertically and then retighten the two 7/16”
nuts to secure the solenoid.
Figure 102
Step 8
Remove the restrictor cap and tool.
Step 9
Sanitize, lubricate, and reinstall the driven spinner
and spinner blade. Install the restrictor cap.
Step 10
Install the front control panel and restore power to
the machine.
Step 11
Dispense several shakes to check for proper draw
valve performance.
Spinner Motor
The spinner motor shaft must be centered in the
draw valve. The spinner blade shaft must insert into
the center of the spinner coupling. (See Figure 103.)
Figure 103
To adjust the alignment, perform the following
steps:
Step 1
Loosen the four screws that secure the spinner
motor to the bracket. With the freezer door
assembly installed, insert the spinner blade into the
coupling.
Step 2
Position the motor so the spinner shaft is centered
with the coupling.
Step 3
Tighten the two front screws.
Step 4
Remove the door to tighten the rear screws.
Spinner Coupling
The coupling must be adjusted so the spinner blade
is recessed 1/32 (0.8 mm) or less in the bottom of
the door spout.
To adjust the alignment, perform the following
steps:
Step 1
Assemble the freezer door.
Step 2
Loosen the top screw that secures the coupling to
the spinner motor shaft.
Step 3
Position the coupling so the bottom of the spinner is
recessed 1/32” (0.8 mm) or less in the bottom of the
door spout.
Step 4
Retighten the coupling screw.