72
Troubleshooting
Model C602
Shake Dispensing Mechanism Troubleshooting (Co nt’d.)
PROBLEM CAUSE REMEDY
4. Draw valve does not fully open
(long draw time).
a. The solenoid bumper screw is
loose.
a. Align the actuator place and
secure the bumper screw to the
solenoid plunger.
b. The draw solenoid is adjusted too
low.
b. Adjust the draw solenoid to the
proper height. (See page 56.)
5. Draw valve will not close. a. The freezer door is improperly
installed.
a. Re-install the freezer door. Tighten
the hand screws in a criss-cross
pattern.
b. Improper lubrication of draw valve. b. Lubricate according to instructions
in the Operator’s Manual.
c. Improper o -rings installed on the
draw valve.
c. Install the correct o-rings - part no.
020571-1 (F treated)
d. The dispensing mechanism is out
of alignment.
d. Re-align the dispensing
mechanism. (See page 55.)
e. The draw valve is binding in the
freezer door.
e. Replace the defective component.
f. The solenoid plunger is binding in
the coil body.
f. Replace the solenoid.
g. The driven spinner has
disengaged from the s pinner blade
assembly.
g. Adjust the spinner coupling. (See
page 57.)