Pump Motor Rotation
1. Remove the air/mix pump assembly.
2. Connect power to the freezer and place the
power switch in the ON position.
3. Press the PUMP key on the control panel. This
will activate the pump motor only.
4. Observe the pump ball crank. It should be
rotating counterclockwise.
If rotation is not correct, refer to the wiring diagram
on the pump motor and re-wire accordingly.
REMEMBER TO DISCONNECT ALL
POWER TO THE FREEZER! Failure to follow this
instruction may result in electrocution.
Electrical Connection s
Each freezer requires one power supply. Check the
data label on the freezer for fuse, circuit ampacity
and electrical specifications. Refer to the wiring
diagram, provided inside the control box, for proper
power connections.
In the United States, this equipment is intended to
be installed in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70-1987. The
purpose of the NEC code is the practical
safeguarding of persons and property from hazards
arising from the use of electricity. This code contains
provisions considered necessary for safety.
Compliance therewith and proper maintenance will
result in an installation essentially free from hazard!
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
Stationary appliances which are not equipped with a
power cord and a plug or other device to disconnect
the appliance from the power source must have an
all-pole disconnecting device with a contact gap of at
least 3 mm installed in the external installation.