SAFETY
3-3
Model C706
Safety
3
NOTICE! Cleaning and sanitizing schedules
are governed by your federal, state or local regulatory
agencies and must be followed accordingly. Please see
the cleaning section of the manual for the proper
procedure to clean this machine.
CAUTION! This machine is designed to
maintain product temperature under 41°F (5C). Any
product being added to this machine must be below 41F
(5C). Failure to follow this instruction may result in
health hazards and poor machine performance.
Do not obstruct air intake and discharge openings:
A minimum of 6 in. (152 mm) air space is required on
both sides and 0 in. (0 mm) on the rear. Failure to follow
this instruction may cause poor freezer performance and
damage to the machine.
For Indoor Use Only: This machine is designed to
operate indoors, under normal ambient temperatures of
70°F to 75°F (21° to 24°C). The machine has
successfully performed in high ambient temperatures of
up to 104°F (40°C) at reduced capacities.
CAUTION! DO NOT run the machine without
product. Failure to follow this instruction can result in
damage to the machine.
Noise Level: Airborne noise emission does not exceed
78 dB(A) when measured at a distance of 39 in. (1.0 m)
from the surface of the machine and at a height of 63 in.
(1.6 m) from the floor.