EasyManua.ls Logo

Taylor C716 - Mix Pump Assembly

Taylor C716
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
Models C708 & C716 Operating Procedures
Step 13
Place the agitator on the agitator drive shaft
housing. (See Figure 50.)
12182
Figure 50
Note: If agitator should stop turning during normal
operation, with sanitized hands, remove agitator
from agitator drive shaft housing and brush clean
with sanitizing solution. Install the agitator back onto
the agitator drive shaft housing.
Step 14
Remove the cotter pin from the pump. Install the top
end of the feed tube into the pump assembly. Place
the cotter pin in position on the outlet fitting of the
pump assembly. (See Figure 51.)
Figure 51
Repeat these steps for the other side of the
Model C716.
Priming
Note: Use only FRESH MIX when priming the
freezer.
Step 1
Place an empty mix pail beneath the door spout(s).
Pour 2-1/2 gallons (9.5 liters) of FRESH mix into the
mix hopper and allow it to flow into the freezing
cylinder.
Step 2
Open the draw valve to remove all sanitizing
solution. When only fresh mix is flowing, close the
draw valve.
Note: Momentarily open the center draw valve to
remove sanitizer from the center door spout (C716
only).
Step 3
When mix stops bubbling down into the freezing
cylinder, remove the cotter pin from the outlet fitting
of the mix pump. Insert the outlet end of the mix
feed tube into the mix inlet hole in the mix hopper.
Place the inlet end of the mix feed tube into the
outlet fitting of the mix pump. Secure with cotter pin.
Figure 52
Step 4
Select the AUTO symbol
.
Step 5
Fill the hopper with fresh mix and place the mix
hopper cover in position.
Repeat these steps for the other side of the
Model C716.