3-2
SAFETY
Models C709 & C717
Safety
3
WARNING! Avoid injury.
• DO NOT allow untrained personnel to operate
this machine.
• DO NOT put objects or fingers in the door spout.
• DO NOT operate the machine unless all service
panels and access doors are fastened with
screws.
• DO NOT remove the machine door or beater
assembly unless the control switches are in the
OFF position.
Failure to follow these instructions may result in severe
personal injury from hazardous moving parts.
WARNING! This machine has many sharp
edges that can cause severe injuries.
Examples:
• Scraper blades
• Condenser fins
• Cup/cone dispenser (if applicable)
IMPORTANT! Access to the service area of
the machine must be restricted to persons having
knowledge and practical experience with the machine, in
particular as far as safety and hygiene are concerned.
CAUTION! This machine must be placed on a
level surface. Extreme care should be taken when
moving for any reason. Two or more persons are
required to safely move this machine. Failure to comply
may result in personal injury or damage to the machine.
NOTICE! Cleaning and sanitizing schedules
are governed by your federal, state, or local regulatory
agencies and must be followed accordingly. Please refer
to the cleaning section of this manual for the proper
procedure to clean this machine.
Do not run the machine without product. Failure to follow
this instruction can result in damage to the machine.
CAUTION! This machine is designed to
maintain product temperature under 41°F (5C). Any
product being added to this machine must be below 41F
(5C). Failure to follow this instruction may result in
health hazards and poor machine performance.
Do not run the machine without product. Failure to follow
this instruction can result in damage to the machine.
Do not obstruct air intake and discharge openings:
• C709—A minimum of 6 in. (152 mm) airspace is
required on both sides and 0 in. on the rear.
• C717—A minimum of 3 in. (76 mm) airspace is
required around all sides. Install the deflector
provided to prevent recirculation of warm air.
For Indoor Use Only: This machine is designed to
operate indoors, under normal ambient temperatures of
70°F to 75°F (21°C to 24°C). The freezer has
successfully performed in high ambient temperatures of
104° (40°C) at reduced capacities.
Noise Level: Airborne noise emission does not exceed
78 dB(A) when measured at a distance of 39 in. (1.0 m)
from the surface of the machine and at a height of 62 in.
(1.6 m) from the floor.