24
Models BC10/BW11Operating Procedures
130620
Step 5
Position the cup so the agitator makes slight contact
with the bottom of the cup.
Figure 11
Step 6
Activate the agitator . Follow the instructions below
based on the specific model:
Standard Unit Without Foot Pedal: Place the
On/Off switch in the ON position.
Standard Unit With Foot Pedal: With the On/Off
switch in the ON position, step on the foot pedal
switch.
Unit Equipped With Timer: With the On/Off
switch in the ON position, press the Start switch.
Step 7
Using a circular motion, work the cup upward and over
the spinning agitator.
Note: Agitation will chip and break down solids. It is
not intended to completely pulverize ingredients. Solid
chunks should be evident in the finished product.
CAUTION: Both the permanent agitator and the spoon
agitator are designed to withstand reasonable contact
with the spinning agitator shaft. However , it should not
be forced or held solidly against the side or bottom of
the cup. This may cause damage to the cup or
components.
Step 8
After about 10 seconds have elapsed, slowly remove
the cup by “swirling” it around the agitator. This will
create an effect that is pleasing to the eye and avoids
leaving a hole in the center of the product.
Step 9
Before removing the cup completely, hold the top edge
of the cup near the spinning agitator to allow excess
mixture to be projected into the cup or the mix- through
collar .
Step 10
Deactivate the agitator. Follow the instructions below
based on the specific model:
Standard Unit Without Foot Pedal: Place the
On/Off switch in the OFF position.
Standard Units With Foot Pedal: Release the
foot pedal.
Unit Equipped With Timer: The machine stops
automatically at the end of the blending cycle.
Step 11
Serve the product. If using spoon agitator, remove the
spoon from the agitator shaft. Serve the product with
the spoon in the cup.
Note: Spoon agitators should be used only once.
Step 12
Permanent Agitators, Only: Prepare a durable
square or rectangular container, filling it to within 1 inch
(30 mm) from the top with an approved cleaning
solution. The container must be deep enough to
submerge the entire agitator and shaft. USE WARM
WA TER (1 10_F/43_C) AND FOLLOW THE MANU-
FACTURER’S SPECIFICATIONS. Do not use a
solution that contains ammonia.
Submerge the agitator in the cleaning solution all the
way to the bottom of the motor chamber. Activate the
agitator and allow it to run for about 15 seconds.
Repeat this step several times, making certain all
portions of the agitator and shaft have been
submerged in the cleaning solution.
Repeat this step using cool, clean water instead of
cleaning solution.
W ARNING: Never try to wipe clean the
agitator while it is active. Failure to follow these
instructions can lead to severe personal injury
from hazardous moving parts, or damage to the
unit.