Controls and Systems
Model SB25
Keypad Calibration
Step 1
Enter the keypad calibration mode by holding the
Stop button until all recipe key LED's blink.
S Press recipe 1 key to change the Shave
calibration value.
S Press recipe 3 key to change the Water
calibration value.
S Press recipe 4 key to change the Cane
calibration value (Model SB25, only).
When the value to be changed has been selected, it
will blink at a slow rate, along with the recipe1 & 2
serving size LED's.
Note: The serving size LED's blink to indicate that
the calibration value can now be changed.
Step 2
Use the +/- buttons to increase or decrease the
calibration settings to achieve the desired results.
Step 3
Press the STOP/CANCEL button to cancel any
unsaved changes and exit the calibration mode.
Step 4
Press the NO SUGAR button to save the current
calibration value and run a test cycle of the item
being calibrated:
S Shave dispense 10 oz of ice with the
current calibration value applied.
S Blend run blender for “2 seconds” with the
current calibration value applied.
S Water - dispense 4 oz of water with the
current calibration value applied.
S Cane - dispense 4 oz of cane with the
current calibration value applied.
S Press “GO” to save the changes.
Test Mode
______________________________
The Test Mode within the Calibration Mode allows
all motors, valves, and pumps to be run manually.
This can be useful in diagnosing motor or dispensing
issues.
Step 1
Enter the calibration mode by holding the
button for 3 seconds.
Step 2
Press and hold the manual blend button
for
3 seconds.
Step 3
Press the single serving button
for shaver or
blender motor testing:
S Press and hold the manual shave button
to run the shaver motor.
S Press and hold the manual blend button
to run the blender motor.
Step 4
Press the double serving button
for water
dispense testing:
S Press and hold the manual shave button
to run the cane pump.
S Press and hold the manual blend button
to activate the water valve.
Step 5
Press the STOP/CANCEL button to exit the Test
Mode.