TCL Air Conditioner Service Manual
19 
 
Improper installation may lead to fire hazard, explosion, electric shock or injury. 
Safety precautions for Installing and Relocating the unit. 
To ensure safety, please be mindful of the following precautions. 
 
    Warnings 
 
When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the 
specified refrigerant. 
Any  presence  of  air  or  other  foreign  substance  in  the  refrigerant  circuit  will  cause  system  pressure  rise  or 
compressor rupture, resulting in injury. 
When installing or moving this unit, do not charge the refrigerant which is not comply with that on the nameplate or 
unqualified refrigerant. 
Otherwise, it may cause abnormal operation, wrong action, mechanical malfunction or even series safety accident. 
When refrigerant needs to be recovered during relocating or repairing the unit, be sure that the unit is running in 
cooling mode. Then, fully close the valve at high pressure  side (two-way valve). About 30-40 seconds later, fully 
close the valve at low pressure side (3-way valve), immediately stop the unit and disconnect power. Please note that 
the time for refrigerant recover should not exceed 1 minute. 
If refrigerant recovery takes too much time, may be cause compressor overheat, resulting in injury. 
During  refrigerant  recovery,  make  sure  that  two-way  valve  and  3-way  valve  are  fully  closed  and  power  is 
disconnected before detaching the connecting pipe. 
If compressor starts running when the valves is open and connecting pipe is not yet connected, air will be sucked in 
and cause pressure rise and then compressor overheat or gas leak, resulting in injury.   
When  installing  the  unit,  make  sure  that  connecting  pipe  is  securely  connected  before  the  compressor  starts 
running. 
If compressor starts running when the valves is open and connecting pipe is not yet connected, air will be sucked in 
and cause pressure rise and then compressor overheat or gas leak, resulting in injury. 
Prohibit installing the unit at the place where there may be leaked corrosive gas or flammable gas. 
If there leaked gas around the unit, it may cause explosion and other accidents. 
Do not use extension cords for electrical connections. If the electric wire is not long enough, please contact a local 
service center authorized and ask for a proper electric wire. 
Poor connection may lead to electric shock or fire. 
Use the specified types of wires for electrical connections between the indoor and outdoor units. Firmly clamp the 
wires so that their terminals receive no external stresses. 
 
Electric  wires  with  insufficient  capacity,  wrong  wire  connections  and  insecure  wire  terminals  may  cause  electric 
shock or fire.