TCL Air Conditioner Service Manual
40 
3.2.6 E9---ODU IPM /Compressor drive fault 
 
If unit have 6 times stopping works for IPM protection (P0) continuously, it will display E9 error, and unit can’t be 
recovered to operation, except press ON/OFF button. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Remark: 
1. F9 code 
Reason: 
The IPM module temperature test circuit failure. 
Solution: Replace the ODU PCB. 
 
2. FA code
 
Reason: The compressor phase-current test circuit failure.
 
Solution: Replace the ODU PCB. 
 
 
Display E9 
Re-power on unit running 
for 30 min, and check the 
failure code display 
Normal protection 
Display F9 or FA first 
then E9
Replace ODU PCB 
Display F5,F6,or F7 first 
then E9 
Solution as F5,F6,or F7 
Display P0 or P2 first 
then E9
Solution as P0 or P2 
Replace compressor 
Yes  
No 
End   
Failure disappear? 
No
Yes