3.2.10 P1--- Over / under voltage protection 
 
1.  Test  voltage  between  L  &N,  When  the  power  supply  V>AC260V  or  V<AC150V,  AC  will  display  P1 
protection, unit will recover back to previous status while V>AC155V. 
2. Test voltage on the big size electrolytic capacitor of ODU PCB, When DC busbar voltage V>DC420V or V
<DC150V, unit will recover back to previous status while DC190V<V<DC410V   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Display P1 
Is the power supply 
voltage btw145-260V? 
Wait until the AC 
volta
e recover
 
Replace ODU PCB 
Yes
Yes
No
No
No
Yes  
No
End   
Wait until the busbar 
voltage recovery 
Unit works 
normal? 
Yes  
Is the power supply 
voltage btw145-260V? 
Is the busbar voltage 
btw150-420V?