EasyManua.ls Logo

TCL TAC-18CSD/XA81I

TCL TAC-18CSD/XA81I
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TCL Air Conditioner Service Manual
55
3.2.21 F7---Module temperature protection.
IPM overtemperature protection, when IPM temperature more than 95, it will show F7.
Display F7
IPM well contact to
heat sink?
Any dust or gap btw
IPM & heat sink?
Clean or adjust the gap
btw IPM and heat sink
Fix the screw
ODU cooling system
abnormal? Compressor
with big running current?
(9,12K:6-7A,
18,24K:7-9A)
Low pressure normal?
0.8-1.2Mpa
IPM temperature
circuit abnormal?
Replace ODU PCB
Is the 2/3way valve
fully opened?
Open the valve
Condenser /
evaporator dirty?
Capillary blocked?
Replace capillary
Clean condenser /
eva
p
orato
r
End
F7 disappear?
Y
es
No
No
No
No
No
No
No
Y
es
Y
es
Y
es
Y
es
Y
es
Y
es
Y
es
Check the screw
fully fasten?
Y
es
No
No
F7 disappear?
No
Y
es
End

Related product manuals