Piping size O.D : mm Length of connecting pipe : m
Refrigerant piping
Max. length : m
A
10
15
Indoor unit
0.40
Gas
9.52
12.7
15.88
Liquid
6.35
9.52
Outdoor unit
0
07K
09K
12K
18K
24K
Models
Refrigerant piping length (one way)
Outdoor unit precharged
(up to 7m)
15m
160
7m
0
10m
60
07K
09K
12K
18
K
MAX. HEIGHT DIFFERENCE
ADDITIONAL REFRIGERANT CHARGE(R-22 : g)
MAX. REFRIGERANT PIPING LENGTH
Calculation : Xg=20g/m (A-7)m
Calculation : Xg=30g/m (A-7)m
Models
Outdoor unit precharged
(up to 7m)
Refrigerant piping length (one way)
15m
240
7m
0
10m
90
24
K
OB207t-1qxp 25/9/97 8:53 PM Page 27
see <<Specification>>
see <<Specification>>
see <<Specification>>
see <<Specification>>
10
TCL Air Conditioner Service Manual

Table of Contents