Level
meter
Equipment:
+
VTVM
*
Oscilloscope
*
AF
oscillator
+
ATT
Overall
distortion
Equipment:
*
Distortion
meter
*
AF
oscillator
*
ATT
*
Oscilloscope
*
Test
tape---C-RA
(reference
blank
tape)
MEASUREMENT
&
ADJUSTMENT
When
standard
recording
level
is
supplied
1.
Test
equipment
connection
is
shown
in
fig.
21.
Bw
AF
Oscillator
LINE
IN
LINE
OUT
ATT
Record
mode
Fig.
21
.
Set
the
bias
selector
to
“LOW”
and
the
EQ.
selector
to
"120uS".
.
Supply
1kHz
signal
(~24dB)
from
AF
oscillator,
through
ATT,
to
LINE
IN
(L-CH)
jack.
.
Adjust
ATT
until
monitor
level
at
LINE
QUT
(L-CH)
jack
becomes
0.42
V
(—7
dB)
and
confirm
that
the
level
meter
indicates
0
VU
posi-
tion.
.
If
in
the
above
condition,
the
level
meter
doesn’t
indicate
OVU
posi-
tion,
change
the
“Connection
points”
of
the
amplifier
pattern,
and
make
the
adjustment.
D
If
the
indication
of
the
left
channel
meter
is
below
—1.5dB,
short
circuit
connection
point
©
as
shown
in
fig.
7.
@
If
the
indication
is
still
insufticient
by
shorting
connection
point
©,
short
circuit
connection
point
©
also
as
shown
in
fig.
7.
.
Adjust
VR11
so
that
the
right
meter
will
indicate
the
same
value
as
the
left
meter.
(See
fig.
28
on
page
17).
REMARKS
*
Record
mode
.
Test
equipment
connection
is
shown
in
fig,
22.
co
ATT
6002
Record
mode
LINE
OUT
law
3
oscillat
AF
oscillator
Test
tape
R/P
head
Playback
mode
Disto
Higa?
meter
Fig.
22
Supply
1
kHz
signal
to
LINE
IN
and
adjust
ATT
so
that
output
jevel
at
LINE
OUT
indicates
0.42
V
(—7dB).
Make
recording.
Playback
and
measure
distortion
factor
of
output
signal.
When
the
distortion
factor
does
not
satisfy
the
standard,
check
the
bias
current.
When
the
bias
current
is
lower
than
standard,
distor-
tion
will
increase.
Care
should
be
exercised
in
the
adjustment
because
the
bias
current
also
has
an
influence
on
the
overall
frequency
response.
Refer
to
"The
overall
frequency
response”
and
"The
bias
current
adjustment”
Test
tape
Standard
value:
|
Less
than
3.0%
(Normal)
|
Less
than
3.5%
(CrO2)
|
*
LINE
IN
level
contro!
*
Bias
selector
++++++++-
LOW
*EQ
selector
+--+
1
(for
Normal
tape)
|
*
Bias
selector
«+--+
*EQ
selector
-.+..+++
(for
CrOz
tape)
20uS
12