RS-M250
ITEM
MEASUREMENT
&
ADJUSTMENT
®
Playback
gain
Condition:
*
Tape
selector
-++
Normal
position
*
Playback
mode
Equipment:
*VTVM
*
Oscilloscope
*
Test
tape
---
QZZCFM
.
Test
equipment
connection
is
shown
in
fig.
2.
.
Playback
standard
recording
level
portion
on
test
tape
(QZZCFM
315Hz,
0dB),
and
using
VT
VM
measure
the
output
level
at
LINE
OUT
jack.
.
Make
measurement
for
both
channels.
Standard
value:
0.7V+1.5dB
Adjustment
L,
2,
If
measured
value
is
not
within
standard,
adjust
VR3
(L-CH),
VR4
(R-CH) (shown
in
fig.
1).
After
adjustment,
check
“Playback
frequency
response”
again.
@
Bias
leakage
Condition:
*
Record
mode
*
Input
level
controls
---
MAX
*
Output
level
control
---
MAX
*
Tape
selector
-+-
Metal
position
Equipment:
*
VTVM
*
Oscilloscope
1.
Test
equipment
connection
is
shown
in
fig.
7.
2.
3.
Adjust
trap
coils
L1
(L-CH),
L2
(R-CH),
so
that
measured
Record/playback
Place
UNIT
into
record
mode.
value
becomes
minimum.
_
Make
adjustment
for
both
channels.
to
POT
VTVM
Oscilloscope
:
R149
(L-CH)
Fig.
7
R150(R-CH)
TP3
ee
TPA
(R-CH)
@
Erase
current
Condition:
*
Tape
selector
-++
Metal
position
*
Record
mode
Equipment:
*
VTVM
*
Oscilloscope
@
Bias
current
Condition:
*
Record
mode
*
Tape
selector
-++
Normal
position
+++
Fe-Cr
position
+++
CrO2
position
+++
Metal
position
Equipment:
*
VTVM
*
Oscilloscope
Overall
gain
Condition:
*
Record/playback
mode
*
Normal
position
*
Input
level
controls
---
MAX
*
Output
level
control
---
MAX
*
Standard
input
level;
MIC
+--+
e+e
—72+3.5dB
LINE
IN
---
~24+3.5dB
Equipment:
*VTVM
*
AF
oscillator
*
ATT
*
Oscilloscope
*
Resistor
(600
2)
*
Test
tape
(reference
blank
tape)
-+QZZCRA
for
Normal
.
Test
equipment
connection
is
shown
in
fig.
9.
.
Place
UNIT
into
record
mode,
and
tape
selector
to
normal
.
Read
voltage
on
VTVM
and
calculate
bias
current
by
following
.
Test
equipment
connection
is
shown
in
fig.
8.
.
Place
UNIT
into
record
mode
and
measure
voltage
at
test
point
1.
.
Determine
erase
current
with
the
following
formula:
Voltage
across
both
ends
of
R272
1
(Q)
|
Standard
value:
145+5mA
(Tape
selector
---
Metal)
VTVM
Osciloscope
Fig.
8
Erase
current
(A)
.
If
measured
value
is
not
within
standard,
adjust
VR9.
€109
(L-CH)
C110
(R-CH):
position.
Record
mode
TP7{R17)
formula:
TP8
(R18)
Value
read
on
VTVM
(V)
VIVM
Oscilloscope
102
Standard
value:
around
330A
(Normal
position)
Bias
current
(A)
.
Adjust
C109
(L-CH)
and
C110
(R-CH) (shown
in
fig.
1).
.
Set
the
tape
selector
to
each
position.
.
Make
sure
that
the
measured
value
is
within
standard.
Standard
value:
around
370A
(Fe-Cr
position)
around
415A
(CrOz
position)
around
700A
(Metal
position)
.
Test
equipment
connection
is
shown
in
fig.
10.
.
Place
UNIT
into
record
mode,
and
normal
tape
mode.
.
Supply
1kHz
signal
(—24
dB)
from
AF
oscillator,
.
Adjust
ATT
until
monitor
level
at
LINE
OUT
becomes
.
Using
test
tape,
make
recording.
.
Playback
recorded
tape,
and
make
sure
the
value
at
.
lf
measured
value
is
not
0.7
V,
adjust
VR5
(L-CH),
through
ATT
to
LINE
IN.
Record
mode
LINE
IN
AF
oscillator
1
tt
0.7V.
ies
R/P
head
Pa
k
=
Playback
mode
“VTVM
Fig.
10
LINE
OUT
on
VTVM
becomes
0.7
V.
vad
tie
Oscitloscope
VR6
(R-CH).
.
Repeat
from
step
2.