This document and all the information contained herei
n are the confidential and exclusive property of TechnipFMC,
and may not be reproduced, disclosed, or made public in
any manner prior to express written authorization by TechnipFMC.
Always ensure that calculated system Net Positive Suction Head available, NPSHa,
exceeds pump Net Positive Suction Head required, NPSHr, by at least 5 feet (1.5
meters) of water for proper operation of the pump. NPSH requirements for each pump
model are provided on the product data sheets available through FMC or your
authorized FMC reseller. FMC does not recommend using the pump in static lift
conditions without prior factory approval.