24
KINESIS STATIONS
B
A
A
REPLACING THE CABLE
Cables must always be replaced at the rst sign of wear, even if only the outer rubber protection is worn.
W
Carefully check the state of the cables once a month.
ALWAYS use cables supplied directly by Technogym.
To replace the cable, remove the rear protection panel as described in the paragraph Anchoring to the oor.
In High Pull, Low Pull, Overhead Press and Press, both weight stacks are operated by the
handgrips.
Lock pawl (A) by inserting a spanner in the hole provided.
Loosen screws (B) on both ends of the handgrip.
Remove pawl (A) and pull out the cable.
Lock pawl (A) to avoid damaging the cable.