29
SKILLROW
TROUBLESHOOTING
Below is a list of problems that may arise during normal use of the equipment. If the described remedies do not solve the problem, contact the Technical
Support Service.
Problem Cause Remedy
Problems in monitoring heart rate
with the chest band
Worn heart rate monitor chest band. Change the chest band.
Chest band transmitter not making proper skin contact. Dampen the inside of the chest band with water.
Damaged transmitter. Change the chest band.
When rowing, the display turns o
immediately or does not turn on.
The battery is at. Recharge the battery.
If the grip does not return completely
to the end of stroke
The elastic is loose. Adjust the length of the elastic as described above.
Braking is not ecient Presence of dust in the fan. Clean the fan as described above.