26
Spazio Forma
Contents
Problem Cause Remedy
Excessive noisiness
Data incorrect or unreliable with
equipment running
Problems in reading heart rate
Equipment not properly levelled
Equipment next to source of radio
interference (e.g. electrical
domestic appliance)
Other transmitters situated nearby
Strong radio interference sources
nearby
Worn chest band
Chest band not making proper skin
contact
Check the position and level
with the adjustment screws (see
section 1.3.4)
Move the equipment to another
place or move the sources of
interference
Move the equipment far enough
away to stop signal interference
(minimum distance between two
units cm 80)
Find the interference source (e.g.
electrical domestic appliance) and
move it away or move Spazio Forma
Contact the Assistance Service
directly for a replacement chest
band
Dampen the inside of the chest band
with water
Danger
There are high voltages inside the motor compartment, therefore the guard must be removed by
authorised personnel only; only authorised personnel can carry out internal repairs.
1 Technical information
1.1 Equipment identification
1.2 Description of the equipment
1.3 Installation and assembly
1.4 Maintenance
1.5 Easily solved problems
1.6 Technical assistance
1.7 Storage
1.8 Scrapping