P2012
AIRCRAFT MAINTENANCE MANUAL
23-00 Communicatio
n
Check communication equipment (including tranponder)
according to local rules.
ATA Item Maintenance Task Frequency
A B C D E
ELECTRICAL POWER
24-00 Electrical
System
Check batteries installation. Inspect battery cables and
housing. Check vent lines free of obstructions.
X
24-00 Electrical
System
Check batteries charging each 6 months and recharge if
necessary according to battery installation Manual
Refer to ATA 24 or CMM
(see True Blue Power
Installation Manual and
Oper. Instruct. - 9018047)
24-00 Electrical
System
Perform visual inspection, charging each 24 months
according to battery installation Manual
Refer to ATA 24 or CMM
(see True Blue Power
Installation Manual and
Oper. Instruct. - 9018047)
24-00 Electrical
System
Perform capacity check each 24 months according to
battery installation Manual
Refer to ATA 24 or CMM
(see True Blue Power
Installation Manual and
Oper. Instruct. - 9018047)
24-00 Electrical
System
Inspect External Power Receptacle for absence of
damage and corrosion.
X
24-00 Electrical
System
Inspect circuit breakers panels for general condition
Electrical and security of installation. Inspect breakers
marking System for their readability and wear
X
24-00 Electrical
System
Remove all inspection caps and inspect all electrical,
wires, connectors and attaching parts for security,
routing, chafing, deterioration, wear and correct
installation. Pay particular attention behind instrument
panel and behind interior covers/panels/roof.
X
24-00 Electrical
System
Inspect Starter Generator for general condition, security
of installation and evidence of heat or arcing.
X
24-00 Electrical
System
Inspect Starter Wire for security of installation, absence
of damaged electrical component and operation.
X
24-00 Electrical
System
Inspect switches for security of installation, damaged
System electrical component and operation.
X
24-00 Electrical
System
Check bus bars for general condition, cleanliness, and
Electrical security of all attachments and
terminals/absence of System corrosion.
X
24-00 Electrical
System
Visually inspect control surfaces electrical bonding
System connection for general condition.
X
05-20-00
Page 37
5
th
Edition - Rev. 0
2022, Jan 14