1.10 Peripheral Units
Braking resistors
7200MA 220V/440V 1~20HP model have built-in braking transistor, and can be
connected external braking resistor between B1/P and B2 when lack of braking
ability. Above 25HP models, need to connect braking unit (on - \ of inverter)
and braking resistors (on B-P0 of braking unit).
Table 4 Braking resistor list
Inverter Braking Unit Braking Resistor
Voltage HP
Rated current
(A)
Model
Number
used
Code NO. Specs.
Number
used
Braking Torque (%)
1 4.8 - -
JNBR-150W200
150W/200Ω
1 119%, 10%ED
2 6.4 - -
JNBR-150W100
150W/100Ω
1 119%,10%ED
220V
1
ψ
/3
ψ
3 9.6 - -
JNBR-260W70
260W/70Ω
1 115%, 10%ED
5 17.5 - -
JNBR-390W40
390W/40Ω
1 119%, 10%ED
7.5 24 - -
JNBR-520W30
520W/30Ω
1 108%, 10%ED
10 32 - -
JNBR-780W20
780W/20Ω
1 119%, 10%ED
15 48 - -
JNBR-2R4KW13R6
2400W/13.6Ω
1 117%, 10%ED
20 64 - -
JNBR-3KW10
3000W/10Ω
1 119%, 10%ED
25 80 JNTBU-230 1
JNBR-4R8KW8
4800W/8Ω
1 119%, 10%ED
30 96 JNTBU-230 1
JNBR-4R8KW6R8
4800W/6.8Ω
1 117%, 10%ED
220V
3
ψ
40 130 JNTBU-230 2
JNBR-3KW10
3000W/10Ω
2 119%, 10%ED
1 2.6 - -
JNBR-150W750
150W/750Ω
1 126%, 10%ED
2 4 - -
JNBR-150W400
150W/400Ω
1 119%, 10%ED
3 4.8 - -
JNBR-260W250
260W/250Ω
1 126%, 10%ED
5 8.7 - -
JNBR-400W150
400W/150Ω
1 126%, 10%ED
7.5 12 - -
JNBR-600W130
600W/130Ω
1 102%, 10%ED
10 15 - -
JNBR-800W100
800W/100Ω
1 99%, 10%ED
15 24 - -
JNBR-1R6KW50
1600W/50Ω
1 126%, 10%ED
20 32 - -
JNBR-1R5KW40
1500W/40Ω
1 119%, 10%ED
25 40 JNTBU-430 1
JNBR-4R8KW32
4800W/32Ω
1 119%, 10%ED
30 48 JNTBU-430 1
JNBR-4R8KW27R2
4800W/27.2Ω
1 117%, 10%ED
40 64 JNTBU-430 1
JNBR-6KW20
6000W/20Ω
1 119%, 10%ED
50 80 JNTBU-430 2
JNBR-4R8KW32
4800W/32Ω
2 119%, 10%ED
60 96 JNTBU-430 2
JNBR-4R8KW27R2
4800W/27.2Ω
2 117%, 10%ED
440V
3
ψ
75 128 JNTBU-430 2
JNBR-6KW20
6000W/20Ω
2 126%, 10%ED
*Note 1: Another choices are listed as below. *Note 2: (JUVPHV-0060 no UL certification)
440V 50HP: (JUVPHV-0060+JNBR-9R6KW16) x 1
440V 60HP: (JUVPHV-0060+JNBR-9R6KW13R6) x 1
*Note 3: When set up braking unit and resistor, please make sure there is adequately ventilated environment and appropriate distance for setting.