Wiring Diagram
MC
NFB
B1/P B2
R/L1
S/L2
S1
S2
S8
S7
S6
S5
S4
S3
1
24V
24VG
/
1
Base block
Source(PNP)
SW3
AO1
AO2
GND
E
CN3
2
E
T/L3
U/T1
V/T2
W/T3
CN6 (RJ45)
1
2
GND
E
+12V
AI1
(-10~10V/0~10V, 20K)
AI2
P
P
DO2
DOG
S(+)
S(-)
PI
PO
-12V
P
P
IM
R2C
R1A
R1B
R1C
R2A
F1
F2
+12V, 20mA
(-10~10V/0~10V/4~20mA, 250)
32K Hz. Max.
V
I ,
SW2
-10V~0~10V
4~20mA/0~10V
0V
Sink(NPN),
/
UP/
DOWN/
100
1, 2
(DC 0~10V)
(PG)
250VAC, 1A
30VDC, 1A
(DC 48V/50mA, Open Collector)
32k Hz. Max.
GND
RS485
DO1
,
P
,
*2
*1
*3
*5
*6
*5
*1220V 1~25HP440V 1~30HP()B2B1, B2
*2S1~S8SW3Source(PNP)Sink(NPN)
*32(AI2)SW3(0~10V/-10~10V)(4~20mA)
*4
*4F1, F2使F1-F2
*5220V 3HP440V 5HP()-12V, R2A-R2CPO-GND
*6220V 2HP440V 3HP()DO2
*5
Braking resistor
F
ast acting fuse
Main circuit
power
Default setting
Forward
rotation/stop
Reversal rotation/stop
Up
command
Down command
Multi-step
speed
command 1
Fault
reset
Jog command
External base
block
Multi-function input
Default setting
Analog output
1
Analog output
2
The third type grounding.
Resistance lower than
100 ohm.
Analog signal output 1, 2
Option Card
(PG)
Multi-function relay
output
Power terminal of digital
signal
250VAC, under 1A
30VDC, under 1A
Multi-function pulse output
RS485 Communication port
Multi-function photocoupler output
AI1 Multi-function analog input
(-10~10V/0~10V, 20KΩ)
AI2 Multi-function analog input
(-10~10V/0~10V/4~20mA, 250Ω)
Default
setting
Safety input contact
GND Mutual terminal of analog signal
-12V Power of analog input
+12V Power of analog input, +12v,20mA
PI Pulse command input 32K Hz.
Max.
Pulse input
External analog input
Connection terminal of shielding
wire
24VG Mutual terminal of digital signal
Means Isolated twisted twire
Means
isolate
d wire
Terminal symbol indicates main
circuit
○ indicates control circuit
Remark:
*1: Only the master circuit of 220V1~25HP and 440 V1~30HP (included) or models of lower capacity with
built-in braking resistor provide terminal B2. The braking resistor can be connected directly between B1
and B2.
*2: The multi-function digital input terminals S1~S8 can be set to Source (PNP) or Sink (NPN) mode
through the
SW3.
*3: Multi-function analog input 2 (AI2) can be set to the voltage command input (0-10/-10-10v) or the current
command input (4~20mA) through the SW3.
*4: Safety input connector F1 and F2 should be shorted so that the inverter outputs properly. When the
safety input is used, please be sure to remove the short-pin between F1 and F2.
*5: Only 220 V 3HP and 440 v 5HP (included) or models above, provide terminals
-12V, R2A-R2C and PO- GND.
*6. Only 220 V 2HP and 440 v 3HP (included) or models below, provide terminal DO2.

Related product manuals